DT06-08SD-CE01 8 Position Brown E-Seal Short End Cap Wire Cable Wire-to-Wire Housing for Female Terminals

Original Part Number: DT06-08SD-CE01

LHE Part Number: 201500811228DDSEN

Number of Positions: 8

Contact Tab Size Series: C1.5

Size (MM): L:33 W:25.3 H:20.5

Seal or Unseal: Seal

Overview:

LHE PN: 201500811228DDSEN
Certification: TUV, IATF16949, ISO14001, ISO9001, CQC, UL, ROHS
MOQ: Most product not have MOQ, Small order can be accepted.
Sample service: Free Samples
Delivery Time: 3-5 Days
Quality Control All goods will be 100% inspected before dispatched
Payment: T/T, Western Union, MoneyGram, PayPal; 30% deposits; 70% balance before delivery.
Shipment: DHL/FedEx/TNT/UPS/EMS/Aramex/SF for samples, By Air or by Sea for batch goods; Airport/ Port receiving.

Enquiry Form


Bus logic state and encoding
The CAN bus has two logic states, namely dominant and recessive. The dominant represents the binary bit “0”, and the invisible represents the binary bit “1”. After receiving the bus message, the CAN transceiver converts the signal level into a logic state, That is, the CAN_H level is subtracted from the CAN_L level to obtain a difference level. Various interferences (such as electric fire systems) have the same effect on the two wires. The difference level obtained after subtraction can filter this common mode. interference.
When high-speed CAN transmits recessive status bits, the level of CAN_H/CAN_L is 2.5V. When transmitting dominant bits, the level on CAN_H is 3.5V, and the level on CAN_L is 1.5V.