DT04-2P-E003 2 Position Gray Seal Short End Cap Housing for Male Terminals

Original Part Number: DT04-2P-E003

LHE Part Number: 101500211221

Number of Positions: 2

Contact Tab Size Series: C1.5

Size (MM): L:44.5 W:17.1 H:17.1

Seal or Unseal: Seal

Overview:

LHE PN: 101500211221
Certification: TUV, IATF16949, ISO14001, ISO9001, CQC, UL, ROHS
MOQ: Most product not have MOQ, Small order can be accepted.
Sample service: Free Samples
Delivery Time: 3-5 Days
Quality Control All goods will be 100% inspected before dispatched
Payment: T/T, Western Union, MoneyGram, PayPal; 30% deposits; 70% balance before delivery.
Shipment: DHL/FedEx/TNT/UPS/EMS/Aramex/SF for samples, By Air or by Sea for batch goods; Airport/ Port receiving.

Enquiry Form


If there is interference or zero point drift in the signal waveform, it can be determined that the fault is caused by the high-voltage connector of the high-voltage component upstream of the measurement point being not connected in place or disconnected, but the low-voltage wiring harness of the high-voltage component is normal, so the duty cycle can still be displayed waveform.
If there is no duty cycle signal, it can be determined that the fault is caused by an open circuit in the wiring harness between the measurement point and the upstream high-voltage components, and the fault points can be checked upstream in turn.
Disconnect the PDU low-voltage wiring harness, and measure the waveform on the interlocking output circuit of the PDU low-voltage wiring harness (normally 11V-12V linear waveform).